Waste containers
The connection system with secure locking prevents the container from being opened without it being connected to the transfer door. Complete safety maintaining seamless containment, easy use and handling to maximise productivity.
JCE MULTIWAY SYSTEM® RANGE IMW 55L RIGID CONTAINER
Principle
– 55-litre rigid container for solid waste, IMW and toxic waste
Characteristics
– Material: Rigid HDPE (High Density Polyethylene)
– Pass-through diameter: 190/150 mm
– Capacity: 55 litres
– Dimensions (L)310x(D)380x(H)594/624 mm
– Radio sterilisation 25 kGy – Non-sterile configuration option
– Incineration: At 850°C (Yellow container CTR 150 050 J® )
– At 1200°C (Blue container CTR 150 050 J® )
– Leak tightness: as per ISO standard 10648-2
– Conformity to the following Normative Requirements NF X 30-511, UN 3291 and UN 3249
Compatibility
– With JCE MWS A 150® transfer door, diameter 150 mm
– With DPTE®-type transfer door, diameter 190 mm
Available models
– Yellow container Ref. CTR 150 050 J®
– Blue container: Ref. CTR 150 050 B®
JCE MULTIWAY SYSTEM® RANGE IMW 35L RIGID CONTAINER
Principle
– 35-litre rigid container for solid waste, IMW and toxic waste
Characteristics
– Material: Rigid HDPE (High Density Polyethylene)
– Pass-through diameter: 190/150 mm
– Capacity: 35 litres
– Dimensions (L)310x(D)380x(H)450 mm
– Radio sterilisation 25 kGy – Non-sterile configuration option
– Incineration: At 850°C
– Leak tightness: as per ISO standard 10648-2
– Conformity to the following Normative Requirements NF X 30-511, UN 3291
Compatibility
– Compatible with DPTE®-type transfer door, diameter 190 mm
Available model
– Container: Ref. CTR 190 035 J®
JCE MULTIWAY SYSTEM® RANGE FLEXIBLE WASTE CONTAINER
Principle
-Flexible container for the aseptic transfer or evacuation of waste
Characteristics
-Flexible and transparent material: PE, PU, PVC, thickness: from 100 μm to 300 μm. Other available materials, please ask for more information
-Pass-through diameter: 190 / 150 / 105 mm
-Capacity: 50, 100 or 150 litres, other sizes available, please ask for more information
-Radio sterilisation 25 kGy – Non-sterile configuration option
-Leak tightness: as per ISO standard 10648-2
Compatibility
-With JCE MWS A 150®, PTS A 105 and PTS A 190 transfer door
-With DPTE®-type transfer door, diameters 105 mm and 190 mm